Model |
MP-U15D12+5 |
OUTPUT |
Output Type |
Dual |
DC VOLTAGE |
﹢5V,+12V |
Rated current |
1.2A,0.5A |
EFFICIENCY (Typ.) |
76% |
Rated power |
15 |
RIPPLE & NOISE (max.) |
150mVp-p |
VOLTAGE TOLERANCE |
±5% |
LINE REGULATION |
±1% |
LOAD REGULATION |
±5% |
SETUP, RISE TIME |
2000mS,30mS/230VAC 3000mS,30mS/115VAC(full load) |
HOLD UP TIME |
50mS/230VAC 15mS/115VAC(overload) |
INPUT |
VOLTAGE RANGE |
90-264VAC OR 127-370VDC |
FREQUENCY RANGE |
47-63Hz |
POWER FACTOR (Typ.) |
|
AC CURRENT (Typ.) |
0.4A/115VAC 0.2A/230VAC |
INRUSH CURRENT(max.) |
30A/115VAC 60A/230VAC |
LEAKAGE CURRENT |
0.75mA/240VAC |
PROTECTION |
OVERLOAD |
150~200% rated output power Protection type : constant power , recovers automatically after fault condition is removed |
OVER VOLTAGE |
115-135% cut off the output,auto-recovery |
OVER TEMPERATURE |
100°C± 5°C (TSW1) detect on heat sink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
SHORT CIRCUIT PROTECTION |
long time short circuit , recovers automatically after fault condition is moved |
WORKING TEMP. |
-10 ~+70°C(Refer to Derating Curve) |
ENVIRONMENT |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-20 ~ +75°C 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/℃(0-50℃) |
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; |
EMC SAFETY STANDARDS |
UL60950-1, TUV EN60950-1 approved |
WITHSTAND VOLTAGE |
I/P-O/P: 3 KVAC I/P-PG: 1.5KVAC O/P-PG: 0.5KVAC |
SAFETY &EMC |
ISOLATION RESISTANCE |
I/P-O/P,I/P-FG,50M Ohms/500VDC/25℃/70%RH |
EMI CONDUCTICN& |
Compliance to EN55022 class B EN61000-3-2.3 GB9254,GB17625.1 |
RADIATION |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11,Class A light industry standard |
MTBF |
≥211Khrs MIL-HDBK-217F(25℃) |
OTHERS |
DIMENSION |
77*41*20mm(L*W*H) |
PACKING |
100pcs/CTN or Customized according to customer demand |
WEIGHT |
0.05KG |
Note: |
|
|
1.All parameters NoT specially mentioned are measured at 230VAC input,rated load and 25℃ ,70%RH temperature. AC intent voltage testing: measured at 50% loading and at the end of connector. |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 2 0 " twisted par-wire terminated with 0.1uF & 47uF parallel capacitor. |
3.Tolerance:includes set up deviation,line regulation and load regulation. |
4.Line regulation is measured from low line to high line at rated load.The power supply is considered a component which will be installed into a final equipment. |
5.The dinal equipment must be re-confined that it still meets.EMC directives. For guidance on how it perform these EMC test,please refer to EMI testing of component power supplies. |