Model
Specification |
1200-24 |
DC output voltage |
24V |
Output voltage range(Note:2) |
±1% |
Rated output current |
50A |
Output current range |
0-50A |
Wave and noise(Note:3) |
240mvp-p |
Inlet stability(Note:4) |
±0.5% |
Load stability(Note:5) |
±0.5% |
DC output power |
1200w |
Efficiency |
83% |
Adjustable range for DC voltage |
21.5~27v |
AC input voltage range |
176-264VAC 47~63Hz;248~370VDC |
Input current |
12A/230V |
AC Inrush current |
60A /230V |
Leakage current |
<3.5mA/240VAC |
Overload proctection |
105%~150% Type:pulsing hiccup shutdown Reset:auto recuvery |
Over-voltage protection |
115%~135% Type:pulsing hiccup shutdown Reset:auto recuvery |
High-temperature protection |
ERH3≥650C~700Cfan on, <=550C~600Cfan off ,>=800C~850C,Cut off output(5~15V)~(24~48V) |
Temperature coefficient |
±0.03%/0C(0~500C) |
Setup,rise,hold up time |
800ms,100ms,20ms |
Working temperature and humidity |
-100C~+600C(Refer to output derating curve),20%~90%RH |
Srore temperature and humidity |
-200C~+850C,10%~95%RH |
Safety standards |
|
EMC standards |
Desgn refer to FCC Part15J classA |